Three control mode: Pre-warm mode control, manual mode control and baby mode control
by micro-computer
Set temperature and baby temperature can be displayed separately
Horizon angle of warmer module and inclination of the bassinet can be adjusted
The panels around bassinet can be turned outward
X-ray cassette under the bassinet
APGAR timer
Timer to count phototherapy time
Failure alarm indication, RS232 connector
Below is spec:Â
Power supply | AC220V-230V/50Hz or AC110V-120V/50-60Hz |
Maximum Power output | 700VA |
Three control mode | Pre-warm mode control, manual mode control and baby mode control by micro-computer |
Baby mode temperature control range | 34.5-37.5°C |
Temperature sensor display range | 5-65°C |
Accuracy of skin temperature sensor | ±0.3°C |
Temperature uniformity of mattress | ≤2°C |
Angle of warmer module | 0°, 30°, 60° for two days |
Inclination of the bassinet | ±10° |
APGAR timer | it will give sound when the unit is tones at 1', 5', 10' |
Failure alarm | over temperature alarm, deviation alarm, sensor failure alarm, power failure alarm, setting alarm, checking alarm and so on |
Wave length of blue light | 420-470nm |
Operating range | 18°C-30°C |
Ambient air movement rate | ≤0.3m/s |
Packing | each unit is packed into one carton |
Dimension | 127cmX82cmX113.5cm |
Gross Weight | 100Kg |
The warmer module, the bassinet, the main column, the mobile stand, the controller, the I.V. Pole and the tray,
with the phototherapy unit, and the Beath resuscitation bag, Infant head fixing unit, the oxygen supplying set
(Low-pressure aspirator, the oxygen cyliders, buoy type oxygen regulator, wall type oxygen regulator)
Optional Configuration: VHA stand, drawer, Baby scale



Three control mode: Pre-warm mode control, manual mode control and baby mode control
by micro-computer
Set temperature and baby temperature can be displayed separately
Horizon angle of warmer module and inclination of the bassinet can be adjusted
The panels around bassinet can be turned outward
X-ray cassette under the bassinet
APGAR timer
Timer to count phototherapy time
Failure alarm indication, RS232 connector
Below is spec:Â
Power supply | AC220V-230V/50Hz or AC110V-120V/50-60Hz |
Maximum Power output | 700VA |
Three control mode | Pre-warm mode control, manual mode control and baby mode control by micro-computer |
Baby mode temperature control range | 34.5-37.5°C |
Temperature sensor display range | 5-65°C |
Accuracy of skin temperature sensor | ±0.3°C |
Temperature uniformity of mattress | ≤2°C |
Angle of warmer module | 0°, 30°, 60° for two days |
Inclination of the bassinet | ±10° |
APGAR timer | it will give sound when the unit is tones at 1', 5', 10' |
Failure alarm | over temperature alarm, deviation alarm, sensor failure alarm, power failure alarm, setting alarm, checking alarm and so on |
Wave length of blue light | 420-470nm |
Operating range | 18°C-30°C |
Ambient air movement rate | ≤0.3m/s |
Packing | each unit is packed into one carton |
Dimension | 127cmX82cmX113.5cm |
Gross Weight | 100Kg |
The warmer module, the bassinet, the main column, the mobile stand, the controller, the I.V. Pole and the tray,
with the phototherapy unit, and the Beath resuscitation bag, Infant head fixing unit, the oxygen supplying set
(Low-pressure aspirator, the oxygen cyliders, buoy type oxygen regulator, wall type oxygen regulator)
Optional Configuration: VHA stand, drawer, Baby scale


Vector V16 NLS is a diagnosis and therapy device. Another well-known method for diagnosing the state of energy in a person - is Kirlian‟s aura-diagnostics . It is used to determine the state of the electromagnetic field of a human in general. Status of individual organs is determined by the configuration of their biofield. NLS-diagnostic method allows the evaluation of the state of bio-energy of each organ individually. The results can be obtained in the form of visual images with the topography of the affected area, as well as the graphical features which allow us to analyze damage to body tissue, allowing more accurately to determine not only the type of injury (inflammation or destruction), but also to clarify the diagnosis.