Model:Â Â YSBN-100ASÂ

Brief introduction:
1.Microprocessor based servo controlled temperature system.
2.The microprocessor-controlled unit allows for three settings: pre-warm, manual or automatic.
3.Alarm functions for safety includes:
  Power failure, temperature deviation,
  Temperature sensor failure , over temperature.
4.APGAR timer to record therapy time                                                                    Â
5.Convenient X-ray cassette under infant bed                                                            Â
6.Heater head can be adjusted  + 90º horizontally                                                     Â
7.Tilt angle of infant bed is adjustable                                                                        Â
8.Halogen Observe light angle is adjustable                                                       Â
9.Transparent protector folded                                                                                   Â
10.Adopts anti-explosion micro crystal quartz infrared radiation tube for its radiation source,the heating is quick and life-span is long                                                          Â
11.Alarms are audible and visual.                                 Â
12.A second thermal cut-out function for more safety                                                                          Â
13.Skin temperature sensor failure protect function avoid over temperature                             Â
14.Temperature deviation can be amended in front panel directly
Standard configuration
Main body (including the radiant source, control system, infant bed, bracket), X-ray cassette , Observe light , I.V.pole, skinÂ
temperature sensor, tray, mattress, transparent protector, castors.
Optional parts: Drawer, RS-232(485) connector
Technical data for mobile infant radiant warmer :
1.Power supply : 110/220V   60/50HzÂ
2.  Power input: ≤1200VA
3. Operating condition
   An ambient Temperature:18°C-30°C
An ambient Relative Humidity: 30%--75%RH
Atmospheric Pressure: 700~1060 hPa
An ambient Air Velocity <0.3m/s
4. Temperature control: 32°C~38°C
5.Temperature control accuracy: ≤0.5°C
6.Mattress temperature uniformity : <2°C
7.Skin temperature sensor accuracy: + 0.3°C
8.Warm-up time: ≤30min
9. Infant bed tilt angle:+ 10°
10.APGAR timer range: ≤24h
11.Heater head horizontal: ±90°
12.Mattress size: 67CM X 54CM
13.Distance from heater to mattress:90CM
Transport and storage
Environment Temperature:-40°C~ +55°C
Environment Relative Humidity: ≤95%
Atmospheric Pressure: 500~1060hPa
Package:
package |
Each unit is packed one case |
Size |
120CMXÂ 70CMÂ XÂ 96CM |
Gross weight |
≤90KG. |
We listed some hospital basic items for your reference as below:Â
One-stop shopping Hospital medical equipment |
X ray room | X ray machine |
Processor | ||
X ray film | ||
Cassette | ||
Intensifying screen | ||
Lead clothings(lead glove, lead glasses, Lead cap, lead apron, lead collar) | ||
Ultrasound | B/w 2D ultrasound | |
2/3/4D color ultrasound | ||
Laboratory room | Chemistry analyzer | |
Hematology analyzer | ||
Microplate elisa reader | ||
Microplate washer | ||
Centrifuge | ||
Pipette | ||
Water bath | ||
Urine analyzer | ||
Operation room | Anesthesia machine | |
Ventilator | ||
Operating lamp | ||
Operation table | ||
Pendant | ||
Medical drill and saw | ||
ECG | ||
Patient monitor | ||
Defibrillator | ||
Infusion pump | ||
Electrocoagulation | ||
Oxygen generator | ||
Electric suction device | ||
Autoclave sterilizer |
For more hospital medical equipment, please go to our homepage and search by catagories. Thanks for your interest!Â




Model:Â Â YSBN-100ASÂ

Brief introduction:
1.Microprocessor based servo controlled temperature system.
2.The microprocessor-controlled unit allows for three settings: pre-warm, manual or automatic.
3.Alarm functions for safety includes:
  Power failure, temperature deviation,
  Temperature sensor failure , over temperature.
4.APGAR timer to record therapy time                                                                    Â
5.Convenient X-ray cassette under infant bed                                                            Â
6.Heater head can be adjusted  + 90º horizontally                                                     Â
7.Tilt angle of infant bed is adjustable                                                                        Â
8.Halogen Observe light angle is adjustable                                                       Â
9.Transparent protector folded                                                                                   Â
10.Adopts anti-explosion micro crystal quartz infrared radiation tube for its radiation source,the heating is quick and life-span is long                                                          Â
11.Alarms are audible and visual.                                 Â
12.A second thermal cut-out function for more safety                                                                          Â
13.Skin temperature sensor failure protect function avoid over temperature                             Â
14.Temperature deviation can be amended in front panel directly
Standard configuration
Main body (including the radiant source, control system, infant bed, bracket), X-ray cassette , Observe light , I.V.pole, skinÂ
temperature sensor, tray, mattress, transparent protector, castors.
Optional parts: Drawer, RS-232(485) connector
Technical data for mobile infant radiant warmer :
1.Power supply : 110/220V   60/50HzÂ
2.  Power input: ≤1200VA
3. Operating condition
   An ambient Temperature:18°C-30°C
An ambient Relative Humidity: 30%--75%RH
Atmospheric Pressure: 700~1060 hPa
An ambient Air Velocity <0.3m/s
4. Temperature control: 32°C~38°C
5.Temperature control accuracy: ≤0.5°C
6.Mattress temperature uniformity : <2°C
7.Skin temperature sensor accuracy: + 0.3°C
8.Warm-up time: ≤30min
9. Infant bed tilt angle:+ 10°
10.APGAR timer range: ≤24h
11.Heater head horizontal: ±90°
12.Mattress size: 67CM X 54CM
13.Distance from heater to mattress:90CM
Transport and storage
Environment Temperature:-40°C~ +55°C
Environment Relative Humidity: ≤95%
Atmospheric Pressure: 500~1060hPa
Package:
package |
Each unit is packed one case |
Size |
120CMXÂ 70CMÂ XÂ 96CM |
Gross weight |
≤90KG. |
We listed some hospital basic items for your reference as below:Â
One-stop shopping Hospital medical equipment |
X ray room | X ray machine |
Processor | ||
X ray film | ||
Cassette | ||
Intensifying screen | ||
Lead clothings(lead glove, lead glasses, Lead cap, lead apron, lead collar) | ||
Ultrasound | B/w 2D ultrasound | |
2/3/4D color ultrasound | ||
Laboratory room | Chemistry analyzer | |
Hematology analyzer | ||
Microplate elisa reader | ||
Microplate washer | ||
Centrifuge | ||
Pipette | ||
Water bath | ||
Urine analyzer | ||
Operation room | Anesthesia machine | |
Ventilator | ||
Operating lamp | ||
Operation table | ||
Pendant | ||
Medical drill and saw | ||
ECG | ||
Patient monitor | ||
Defibrillator | ||
Infusion pump | ||
Electrocoagulation | ||
Oxygen generator | ||
Electric suction device | ||
Autoclave sterilizer |
For more hospital medical equipment, please go to our homepage and search by catagories. Thanks for your interest!Â




Dental Foot Pedal,Usb Foot Pedal,Pneumatic Foot Pedal