Steam generator design requirements for large steam boiler manufacturers
One of the most important aspects of the pure steam generator is the design of the sterilization and sterilization system. The materials used by various pharmaceutical companies are generally 316L stainless steel. In order to avoid the corrosion of stainless steel, a more perfect design is needed in the process of pure steam circulation distribution!
1. The pure steam output pressure varies with the process requirements, and a pressure transmitter is installed at the output of the pure steam generator.
2. Ensure that all points of use can be sterilized and sterilized by pure steam. The pure steam flow rate in the pipeline is designed to be less than 25 m / s; it is recommended to install a pure steam condensate trap at each point of use. This steam trap should be selected to make the condensate produced during the sterilization and sterilization process. Can be discharged in time
3. Suitable disinfection and discharge devices, such as safety valves or rupture discs, should be equipped on the container equipment for disinfection and sterilization.
4. In order to ensure the sterilization and sterilization temperature (generally 121 ° C), a temperature sensor or transmitter is installed at each point of use to monitor the temperature.
5. Start timing when the cold spot temperature reaches the disinfection/sterilization temperature
Ungrouped,High Quality Ungrouped,Ungrouped Details, CN
Shenzhen Guangyang Zhongkang Technology Co., Ltd. , https://www.szlighttherapymachine.com